0900-0999 (Accessories)

0901 Invalid filter name: name

The FILTER name specified in the parameter file is not the name of a filtering routine in the Support Library. Either correct the name in the parameter file or use the GenFormat program to define the filter to the Support Library and recompile it. Make sure that you entered the correct library name for the SUPPORT parameter.

0902 Invalid format name: name

The FORMAT name specified in the parameter file is not the name of a formatting routine in the Support Library. Either correct the name in the parameter file or use the GenFormat program to define the format to the Support Library and recompile it. Make sure that you entered the correct library name for the SUPPORT parameter.

0903 Support SETUP failed; Accessory version = version

The DBSETUP entry point in the Support Library returned an error. Typically, this means one of the following:

You entered an incorrect SUPPORT library title in the parameter file.

—or—

The Support Library needs to be recompiled.

0904 Interface version mismatch

DBEngine and the accessory were compiled with different versions of the DATABridge API. Copy the correct version of the DATABridge software and rerun the accessory. If you are running a user-written accessory, recompile it with the correct DBInterface file (SYMBOL/DATABRIDGE/INTERFACE).

0905 Another program opened filename EXCLUSIVE

filename is the name of a parameter file. This message appears when an accessory attempts to access its parameter file and some other program has opened it EXCLUSIVE. Usually this indicates that another copy of the accessory is already running and using the same parameter file. Determine which program has the parameter file opened EXCLUSIVE and either wait for it to finish or manually terminate it. Then, rerun the accessory.

0906 Syntax error in parameter file

This message indicates that there is an error in the parameter file. It is preceded by a more descriptive message indicating the line number and column number of the syntax error.

0907 Missing entry point entrypoint in DBSupport

The accessory tried to use an entry point in DBSupport that was not in the Support Library. Recompile DBSupport or correct the user-written accessory and try again.

0908 Duplicate entry for STR# structurenumber

This message indicates that there is a duplicate structure number (and record type) in the accessory’s parameter file. This is usually the result of a mistake in editing the file. Correct the parameter file and rerun the accessory.

0909 Initialization failed

The accessory detected errors when it tried to initialize. See the accessory’s report file for the specific error message.

0910 Duplicate option (at line nnn): option

Check the following:

Does the parameter file contain a duplicate entry for a SOURCE (for example, two SUPPORT entries)? If so, remove the duplicate entry.

Does the parameter file contain a duplicate entry for a STOP command (for example, two STOP BEFORE commands)?

0911 Parameter file not available: filename

The accessory was unable to find the parameter file or the file is not available to be opened exclusively. Copy the sample parameter file as the name of the missing file and rerun the accessory.

If DBTwin returns this error, copy the sample parameter file as DATA/TWIN/databasename/CONTROL, modify it so that it matches the DBServer SOURCE on the primary system, and rerun DATABridge Twin.

0912 Invalid time limit=hh:mm

The time you entered for the STOP option is invalid for any of the following reasons:

The value for hours (hh) is outside of the valid range of 0 to 23.

The value for minutes (mm) is outside of the valid range of 0 to 59.

Correct the time and run the accessory again.

If DBTwin returns this error, see "STOP" in the DATABridge Twin Administrator's Guide.

0913 Invalid date limit=mm/dd/yyyy

The date you entered for the STOP option is invalid for any of the following reasons:

The day is invalid for the specified month (for example, February 30, September 31)

The month is 0 or greater than 12

The year is between 100 and 1970

Correct the date and run the accessory again.

0914 Invalid number of days = days

The number of days you entered for the STOP option (DBTwin) is invalid because it caused the date to be before 1970. Correct the number and run the accessory again.

0915 Time should be 14 digits: time

A data set entry in the parameter file contains a date/time that is not 14 digits long. Enter it using the following syntax: YYYYMMDDhhmmss

0916 Error writing to filename

This message indicates a problem with a WRITE command on one of the accessory’s output files. This problem might be a hardware problem. If the hardware is functioning properly and the error message persists, contact Technical Support.

0917 n Errors in parameter file filename

The accessory detected n errors in the parameter file. Correct the errors and rerun the accessory.

0918 Line n Error

The parameter file contains an error on line n. Correct the error and rerun the accessory.

0919 Error reading filetitle

The accessory encountered an error while trying to read filetitle.

0921 EOF reading filetitle

The accessory encountered the end-of-file while trying to read filetitle.

0999 Fatal error

The program or accessory encountered an error condition that won’t allow it to continue processing. The program will terminate. Some of these conditions include the following:

Syntax error in the parameter file

An error retrieving the creation date and time

Software version mismatch

An error during initialization

A failure in actually switching the audit file